IMOINSA has announced the delivery and installation of a Himoinsa HTW 1260 T5 generator set in a 16-ton container with reinforced soundproofing, integrated 500 kw load bank, on a slab with our partner ATM Levage to a laboratory equipment supplier based in France. The genset is sup[plied with quality certification ISO 9001 and is compliant with EC mark which includes the following directives:

• 2006/42/CE Machinery safety.

• 2014/30/UE Electromagnetic compatibility.

• 2014/35/UE electrical equipment designed for use within certain voltage limits

• 2000/14/EC Sound Power level. Noise emissions outdoor equipment. (amended by

2005/88/EC)

• EN 12100, EN 13857, EN 60204

The genset can supply

- Prime Power (PRP):

According to ISO 8528-1:2018, Prime power is the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output (Ppp) over 24 h of operation shall not exceed 70 % of the PRP.

- Emergency Standby Power (ESP): According to ISO 8528-1:2018, Emergency standby power is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the

maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP

- Continuous Power (COP): According to Standard ISO 8528-1:2018, this is the maximum power available for continuous loads for unlimited running hours a year between the maintenance times recommended by the manufacturer under the environmental conditions established by the same.

- Data Center Power (DCP): The manufacturer declares an acceptable average daily and annual load factor of 100%. Overload margin: +10%. Operating hours per year: Unlimited (For data center applications located in countries with a stable network). Uptime Institute Compliant: Tier III & IV. "Class G2" performance according to the load impact test according to ISO 8528-5:2018.

Posted 
Jan 25, 2024
 in 
Gensets
 category
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

More from 

Gensets

View All

Join Our Newsletter and Get the Latest
Posts to Your Inbox

No spam ever. Read our Privacy Policy
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.